100609407Which of the following is known as the "silent killer"? A: Carbon dioxide B: Carbon tetrachloride C: Carbon monoxide D: MonodioxideC: Carbon monoxide0
100609408___________ ventilation is a control strategy used to maintain a high oxygen content in buildings where a healthy environment is of particular concern. A: Demand B: Outside C: Purge D: SmokeA: Demand1
100609409The most economical means of measuring the amount of oxygen deprivation in an occupied space is thru the use of: A: A carbon dioxide sensor B: A oxygen sensor C: A nitrogen sensor D: A smoke detectorA: A carbon dioxide sensor2
100609410Which of the following is the natural result of combustion? A: Carbon dioxide B: Water vapor C: Carbon monoxide D: All of the aboveD: All of the above3
100609411The most serious result of incomplete combustion in any fuel burning heating device is: A: Carbon dioxide B: Water vapor C: Carbon monoxide D: NitrogenC: Carbon monoxide4
100609412Carbon monoxide poisoning is often mistaken for: A: The flu with a headache B: Cancer C: A mild cold D: None of the aboveA: The flu with a headache5
100609413Carbon monoxide is measured in: A: Microns B: PPM C: Inches of water gage D: PercentB: PPM6
100609414Outdoor air intake dampers should be located away from: A: Busy ground level intersections B: Loading docks C: Sewer vents D: All of the aboveD: All of the above7
100609415"Infiltration" is: A: Air that enters a space without filtration or control B: Air that enters a space without filtration C: Air that leaves a building thru cracks and unchecked door seals D: None of the aboveA: Air that enters a space without filtration or control8
100609416"Off-gasing" is: A: The release of volatile compounds from products and construction materials B: Usually harmful compounds and chemicals which slowly enter living spaces over time C: Chemicals released into the air especially as the host material is heated D: All of the aboveD: All of the above9
100609417In the science of indoor air quality VOC stands for: A: Vocational Occupational Contaminants B: Volatile Occupational Contaminants C: Volatile Offgasing Contaminants D: Volatile Organic CompoundsD: Volatile Organic Compounds10
100609418Which of the following are common symptoms of carbon monoxide poisoning? A: Headache and nausea B: Fatigue and dizziness C: Shortness of breath D: All of the aboveD: All of the above11
100609419Nitrogen dioxide is a toxic resulting from: A: The process of combustion B: Rapid oxidation C: Both a and b are correct D: Neither a nor bC: Both a and b are correct12
100609420The quality of air indoors can often be worse than that of the outdoors. A: TRUE B: FALSEA: TRUE13
100609421"Mitigation" means: A: To alleviate B: To increase C: To take legal action D: To documentA: To alleviate14
100609422Solid particles suspended in air are measured in: A: Microns B: Parts per million C: Milligrams D: Hundredths of an inchB: Parts per million15
100609423Which of the following organizations has legal oversight over air quality in the United States? A: EPA B: ARI C: RSES D: ASHRAEA: EPA16
100609424The higher the velocity of the air thru a fiber filter the: A: More effective the filtration B: The less effective the filtration C: Air velocity had no affect on filtration D: None of the above is correctB: The less effective the filtration17
100609425At what level of indoor air carbon monoxide do most fire departments require emergency personnel to wear self contained breathing gear (SCBA)? A: 8 ppm B: 35 ppm C: 50 ppm D: 100 ppmC: 50 ppm18
100609426The function of an ERV is to: A: Exchange heat between exhaust and intake air B: Control the static pressure in the main trunk duct C: Control the supply water pressure in high-rise buildings D: Prevent the accumulation of VOCs in the fresh air intakeA: Exchange heat between exhaust and intake air Energy Recovery Ventilation19
100609427ASHRAE standard 55-1992 specifies the conditions likely to be thermally acceptable to _______ percent of adult occupants of a conditioned space. A: 50% B: 60% C: 75% D: 80%C: 75%20
100609428Indoor air quality is legally the responsibility of: A: The building owner B: The business leasing the building C: Those operating and maintaining the building D: All of the aboveD: All of the above21
100609429Clean rooms are classified according to: A: The particle count per cubic foot of air B: Microns allowed per square foot of surface area C: Parts per million allowed per cubic centimeter D: Percent of filtration at 700 fpm of linear airflowA: The particle count per cubic foot of air22
100609430HEPA stands for: A: High Efficiency Particulate Air filter B: High Efficiency and Performance Air filter C: Highly Effective Performance Air filtration D: Heating Efficiency Performance AssociationA: High Efficiency Particulate Air filter23
100609431The internal static pressure in a building should be approximately: A: 0.5 inches higher than the outside air pressure B: 0.05 inches higher than the outside air pressure C: 0.5 inches lower than the outside air pressure D: 0.05 inches lower than the outside air pressureB: 0.05 inches higher than the outside air pressure24
100609432Activated charcoal is often satisfactory for the removal of: A: Gas-phase toxic or odorous pollutants B: Particulates of .5 microns or larger C: Particulates of 12 microns or larger D: Fibrous insulation suspended in airA: Gas-phase toxic or odorous pollutants25
100609433A __________ biological safety cabinet is a gastight negative pressure containment system that provides a physical barrier between the agent and the worker. A: Class 1 B: Class 2a C: Class 2b D: Class 3D: Class 326
100609434Is refrigerant oil that has gone thru a compressor burn-out classified as a toxic waste? A: Yes, if the oil contains a substance classified by the EPA as a toxic waste B: Yes, because it contains acids C: Yes, the EPA classifies all substances that have burned as toxic waste D: No, none of the above is correctA: Yes, if the oil contains a substance classified by the EPA as a toxic waste27
100609435Three common methods used to mitigate poor indoor air quality are: A: Filtration, ventilation and exhaust B: Filtration, capture and exhaust C: Capture, removal and reduction D: Removal, reduction and retentionA: Filtration, ventilation and exhaust28
100609436A micron is: A: One 1,000th of an inch B: One 10,000th of an inch C: One 25,400th of an inch D: One millionth of an inchC: One 25,400th of an inch29
100609437Bacteria, molds, pollen, and viruses are types of: A: Chemical contaminants B: Biological contaminants C: Combustion contaminants D: Physical contaminantsB: Biological contaminants30
100609438According to the World Health Organization approximately what percentage of buildings suffers from SBS (Sick Building Syndrome)? A: 10% B: 15% C: 25% D: 30%D: 30%31
100609439A key factor in solving indoor air quality problems is to: A: Carefully measure the types and quantity of contaminants B: Locate and isolate the source of the pollution C: Ensure all occupants are aware of the problem D: Keep exact records of the actions takenB: Locate and isolate the source of the pollution32
100609440Which of the following steps would be the first step in the process of investigating an indoor air quality problem at a building? A: Conducting an IAQ survey B: Reviewing the HVAC system type and condition C: Performing a full-scale IAQ assessment D: Defining the perceived problemD: Defining the perceived problem33
100609441Physical stressors are those factors which: A: Can be sensed, felt, seen or heard B: Make the occupant uncomfortable C: May include factors the occupant is not aware of D: All of the aboveA: Can be sensed, felt, seen or heard34
100609442Sick Building Syndrome is highly suspected when: A: 20% or more of the building occupants complain with physical symptoms within a two-week period B: A high degree of occupants call in sick with symptoms of headaches, fatigue, dizziness, coughing and nausea C: A high degree of occupants find that their symptoms are alleviated by leaving the building D: All of the aboveD: All of the above35
100609443During an initial pre-investigatory building walk-thru which of the following measurements may be taken? A: Nitrogen dioxide, carbon monoxide and tobacco smoke readings B: Volatile compounds, oxides and radon measurements C: Readings for particulate count and biological sampling D: Carbon dioxide, temperature and relative humidity readingsD: Carbon dioxide, temperature and relative humidity readings36
100609444Which of the following gases lead the list as originating from manmade materials within a building? A: Nitrous oxide B: Carbon monoxide C: Nitrogen dioxide D: FormaldehydeD: Formaldehyde37
100609445Which of the following are psychosocial factors affecting personal comfort: A: The presence of residual tobacco smoke in the building B: The presence of carbon dioxide in the air C: The amount of personal work space and quality of furnishings D: None of the aboveC: The amount of personal work space and quality of furnishings38
100609446Which of the following can affect the intensity of a person's reaction to an irritant in the air? A: Temperature B: Humidity C: Temperature and humidity D: Presence of others in the areaC: Temperature and humidity39
100609447A fairly common but not regularly recognized source of poor indoor air quality and increased dust and residue in homes is: A: The use of candles B: Synthetic carpets C: Down filled comforters D: Computer monitorsA: The use of candles40
100609448Which of the following substances has been directly attributed to as many as 20,000 cases of lung cancer in the United States? A: Radon gas B: The use of candles C: High levels of carbon dioxide D: High levels of nitrogenA: Radon gas41
100609449Concentrations of radon gas is measured in: A: Picocuries B: Microns C: Ppm D: MicrogramsA: Picocuries42
100609450Particulates are categorized in terms of: A: Size and source B: Size and density C: Density and diameter D: Size and colorA: Size and source43
100609451Excessively high concentrations of carbon dioxide in indoor air is usually an indication of: A: A lack of ventilation air B: An increased rate of infiltration air C: SBS D: Tobacco smoke in the airA: A lack of ventilation air44
100609452Which of the following IAQ problems was first discovered to have it source in HVAC cooling towers? A: Legionnella B: Poor air distribution C: Inadequate makeup air D: RadonA: Legionnella45
100609453Organic compounds are: A: Compounds which contain carbon B: Compounds which contain synthetics C: Compounds consisting of radioactive elements D: Those which can only be created in a laboratoryA: Compounds which contain carbon46
100609454A compound is: A: A material made up of two or more elements electrically bound to one another. B: A material made up of three or more elements chemically bound to one another. C: A material made up of excess electrons D: A naturally occurring elementA: A material made up of two or more elements electrically bound to one another.47
100609455TLV stands for: A: Threshold Limit Value B: Threshold Limit Vortex C: Theoretical Limit Value D: Theoretical Lowest ValueA: Threshold Limit Value48
100609456The average urban outdoor air concentration of carbon dioxide has been determined to be: A: 40 ppm B: 400 ppm C: 4,000 ppm D: 40,000 ppmA: 40 ppm49

Need Help?

We hope your visit has been a productive one. If you're having any problems, or would like to give some feedback, we'd love to hear from you.

For general help, questions, and suggestions, try our dedicated support forums.

If you need to contact the Course-Notes.Org web experience team, please use our contact form.

Need Notes?

While we strive to provide the most comprehensive notes for as many high school textbooks as possible, there are certainly going to be some that we miss. Drop us a note and let us know which textbooks you need. Be sure to include which edition of the textbook you are using! If we see enough demand, we'll do whatever we can to get those notes up on the site for you!